Line-Gene K fluorescence quantitative PCR
Features:
The system receives the technical characteristics of Line-Gene consistently, using advanced thermoelectric semiconductor refrigeration technology and optical fiber technology. Constant current power supply and multi-point temperature control mode unique, so that the heating and the cooling module and fluorescence detection module of the technology is more mature, with quick change, precise temperature control, excellent performance and low power consumption.

The system uses a modular design, with a variety of configuration options, and additional temperature gradient, the sample at 4 °C, electric heat preservation cover, automatic dehumidifying and other, more stable, more powerful, more humane design. Can adapt to different levels of customer requirements. Fully meet the needs of scientific research and clinical broader demand.

Specifications:

Model

FQD-48A(A4)
(A4: means automatic lid and 4 channels)

FQD-48A(M2)
(M2: means manual lid and 2 channels )

Sample Capacity

48*0.2ml

48*0.2ml

Sample Volume Range

10~100μL

10~100μL

Dynamics Range

1~10 10 Copies

1~10 10 Copies

Max.Channel Number of
Fluorescence Detection

4 Channels

2 Channels

Excitation Wavelength
( 450-590mm)

Standard channels:    F1:470nm
F2:523nm   F3:543nm   F4:571nm

F1:470nm   F2:523nm

Emission Wavelength

Standard channels:    F1:525nm
F2:564nm   F3:584nm   F4:612nm

F1:525nm   F2:564nm

Detected Fluorescence

F1 :FAM,SYBR Green I;
F2 : HEX,VIC                   
F3 : TAMRA,JOE,Cy3      
F4 : TEX RED,ROX         

F1 : FAM,SYBR Green I;

F2 : HEX VIC                  

Temp.Range

4 °C ~99.9 °C

4 °C ~99.9 °C

Heating Rate ( Max)

> 4.0 °C /sec

> 4.0 °C /sec

Cooling Rate ( Max)

> 4.0 °C /sec

> 4.0 °C /sec

Temp.Uniformity of Block

< 0.3 °C

< 0.3 °C

Temp.Control Accuracy

< 0.1 °C

< 0.1 °C

Gradient Temp.Range

1 °C ~24 °C

1 °C ~24 °C

Hot-lid Temp.Range

80 °C ~110 °C

80 °C ~110 °C

Operation System

Windows 2000/XP

Windows 2000/XP

Power Supply

AC110~220V    50Hz/60Hz    650W

AC110~220V    50Hz/60Hz    650W

Dimension

520*450*320( L*W*H )

520*450*320( L*W*H )

Net Weight

25kg( Without Computer )

25kg( Without Computer )

Certificater

                                          Ferrotec Pelitier / MET CE / RoHS / CE-IVD