MSA99 Pulmonary Function Analyzer

Technical Specifications
1.The portable pulmonary function measurement instrument can be used tomeasure vital capacity (VC), forced vital capacity (FVC), Maximum Ventilatory Volume (MVV). Measurement algorithm refers to the ITS, ERS standards of the American Thoracic Society (ATS)
2.Adopting pressure-flow sensor, sensitive, precise, easy to launder, clean and durable
3.All parameters can be displayed on the oversized screen(320x240), built-in memory can store maximum 300 cases of patient measurement results
4.The instrument can calibrate automatically, all English operation, more convenient to operate
5.110mm thermal printer built-in, can print out a clear clinical report, predicted value, measured value
6.Measurement of breathing time: VC time 50 seconds, FVC measuring time 25 seconds, MVV time 12 seconds, in favor of the coordination between patients and the device
7.Compact and flexible

Product Specifications:

VC

Vital Capacity

ERV

Expiratory Reserve Volume

IRV

Inspiratory Reserve Volume

TV

Tidal Volume

IC

Inspiratory Capacity

FVC

Forced Vital Capacity

FEV0.5

Forced Expiratory Volume in 0.5s

FEV1.0

Forced Expiratory Volume in 1s

FEV3.0

Forced Expiratory Volume in 3s

FEV1.0%G

Forced Expiratory Volume in 1s/Forced Vital Capacity

FEV1.0%T

Forced Expiratory Volume in 1s/Vital Capacity

FEV3.0%G

Forced Expiratory Volume in 3s/Forced Vital Capacity

FEV3.0%T

Forced Expiratory Volume in 3s/Vital Capacity

Vext

Volume of Expiration

Ex Time

Expiratory Time

MMF

The maximum mid-expirator flow, same as MMEF

PEF

Peak Expiratory Flow

MEF75

Maximum Expiratory Flow when 75% FVC remains, same as FEF25

MEF50

Maximum Expiratory Flow when 50% FVC remains, same as FEF50

MEF25

Maximum Expiratory Flow when 25% FVC remains, same as FEF75

FIVC

Forced Inspired Vital Capacity

FIV0.5

0.5s Forced Inspired Volume

FIV1.0

1s Forced Insipred Volume

FIV1.0/FVC

Forced Inspired Volume in 1s/Forced Vital Capacity

FIV1.0/FIVC

Forced Inspired Volume in 1s/Forced Inspired Vital Capacity

PIF

Peak Inspiratory Flow

MIF50%

Inspiratory Flow in 50% Inspired Capacity

MVV

Maximum Voluntary Ventilation

RR

Respiratory rate per minute

TV

Tidal Volume in MVV measurement

 