PA700B Ventilator

Features:
1. Operating Modes: Pneumatically driven & electronically controlled, closed, semi-closed and semi-open
Pneumatically driven electrically controlled ventilator, can be used for emergency clinical resuscitation and respiratory therapy
2. Nonhazardous environmentally friendly frame, precise construction, elegant design, equipped with automated self-checking function during startup and an automatic self-calibrating sensor
3. Display: Built-in 10.4 inch high visibility color TFT display, able-simultaneously display Pressure-Time and Frequency-Time waveforms in real time
4. Sigh: Ability to insert 1-8 sigh breaths in every 100 breaths, ventilation should be no less than 1.5 the tidal volume
5. Equipped with infrared turbine flow sensor; precisely measures gas flows, stable and reliable
6. Power Failure Support Functions: Automatically converts-standby mode during AC power outages
7. 9 Level adjustable humidifier
8. Monitor Parameters: tidal volume, respiration rate, airway pressure, I:E ratio, inspiratory & expiratory status, inspiratory trigger and others
9. Alarms: Audible and/or visual alarms for ventilation volume, tidal volume, oxygen concentration, asphyxia, airway pressure, intubation disconnection, low oxygen, power failure and other alarms, also features a alarm history query function

Advanced Model Exclusive Features
Equipped with professional medical grade air compressor tailored for long clinical times and low noise requirements

Air Compressor
Air Compressor: 220V AC±10%, 50±1Hz, 700VA, also features good protective grounding against electrical activity
Output Gas Pressure: 0.4MPa±20%
Continuous output gas flow greater than or equal to 20L/min
Instantaneous output gas flow great than equal to 60L/min

Specifications:

Model

PA700B Standard Model

PA700B Advanced Model

Display

10.4 inch high visibility color TFT display

Ventilation Mode

A/C, IPPV, SIPPV, IMV, SIMV, Standby, SPONT MANUAL

Minute Volume

Greater than or equal to 18L

Back-up Power Supply

At least 4 hours

Tidal Volume

Adjustable range: 50-1500ml, Display range: 0-2000ml

Respiratory Rate

1-99bpm

Inspiratory/expiratory (I:E) Ratio

4:1-1:4

PEEP

0-10cm H2O

SIMV Rate

1-20bpm

Inspiratory Pressure Trigger

. -10-10cm H2O

Inspiratory Plateau

Adjustable from 0-50% of inspiratory time

Adjustable Oxygen Concentration

45-100%

21-100%

Air Compressor

No

Yes

Gas Supply Requirement

280~600 kPa medical grade oxygen and compressed air supply

Pressure Limit

1.0kPa~6.0kPa

Maximum Safe Operating Pressure

≤ 6.0kPa

Tidal Volume Alarm

Upper Limit: 10~2000ml, Lower Limit: 0~1800ml

Airway Pressure Alarm

Upper Limit: 0.1~6kPa, Lower Limit: 0~5kPa

Oxygen Concentration Alarm

Upper Limit: 22~100%, Lower Limit: 21~80%

 